Gas station equipment technician - dispenser weekly-maintenance checklist - five groups (nozzle and hose, cabinet and display, filter condition, vapor recovery, base and visual-inside), each item with a pass criterion, this week's action, and whether the pump must be off; log per nozzle with the technician's name - leaks, dead auto-shutoff or new noises go straight to tag-out, never into next week's queue
You are a gas station equipment-maintenance coach. Write a
"dispenser weekly-maintenance checklist" for me, printable, one row
per nozzle. Run it in the off-peak window, nozzle by nozzle; the
nozzle under maintenance is tagged out.
Five groups; each item in three columns - "pass criterion / this
week's action / pump off?":
Group 1 - nozzle and hose:
- Hose exterior: no crazing, bulges or cuts; no seep at either
fitting / full-length visual, wipe clean / stays on
- Auto-shutoff: click-off works on a test or observed fill / one
test click-off / stays on
- Nozzle spout and vapor ports: unblocked, no fuel gum / clean the
spout / stays on
Group 2 - cabinet and display:
- Unit upright; nameplate and verification certificate in place
and current / visual / stays on
- Display, keypad, receipt slot working / run one real
transaction / stays on
Group 3 - filter condition (changes follow the maker's interval;
this checklist only records state):
- Nozzles whose flow clearly dropped since last maintenance: log
"recommend early filter change" with the volume-through figure
/ stays on
Group 4 - vapor recovery:
- Vacuum pump sound normal, recovery hose undamaged / listen and
look / stays on
- Face-cone seals aged or notched (affects recovery sealing): log
for replacement / stays on
Group 5 - base and interior visual:
- Base fill sand dry, no fuel traces / visual, top up sand /
pump off, tagged
- At whatever is visible per procedure: no seep marks, belts (if
fitted) uncracked / after tag-out / pump off, tagged
- Anything behind an explosion-proof enclosure [qualified
personnel]: log the symptom only, route the fix to qualified
staff - this checklist contains no enclosure-opening steps
Logging and exception rules:
- One row per nozzle: nozzle number, five group ticks, anomaly
description, technician's signature, date
- Seeps, dead auto-shutoff, new noises: tag out on the spot and
into the repair flow - never into a "next week" queue
- The same anomaly two weeks running: list the nozzle separately
and escalate to the manager for a service decision
Constraints:
- Criteria are see-hear-test; "performs well" may not appear -
it has no way to be checked
- Intervals and air-to-liquid values are never invented - blank
fields [ ] keyed to the maker's manual and the latest test
report
- One full-station pass fits half a day; if it doesn't, cut items,
not time
Why it is written this way
The "pump off?" column is what separates this sheet from a generic maintenance form. Weekly maintenance happens while the station trades, and which items fit between customers versus which need a tag-out decides whether it happens at all - an all-tag-out checklist eventually becomes "too busy today, next week together". Compressing the tag-out items to the minimum (base and interior visual) and designing everything else as on-the-fly checks lets maintenance nest inside two off-peak hours instead of demanding a scheduled shutdown.
The filter group records state rather than performing the change on purpose. Change intervals belong to the manufacturer's manual and differ by model; hard-coding a number into the checklist produces either over-changing or overdue changing - both worse than logging "flow dropped since last time, recommend early change". The sheet's job is to leave evidence for the next document layer to decide on, the same two-layer discipline the rest of the station's tools follow.
"The same anomaly two weeks running gets escalated" is the chronic disease screen. Week by week, every anomaly can be absorbed by "logged, parts on order"; across two weeks, a lazy shutoff or a returning noise means small repairs are papering over a real fault, and the nozzle deserves a service decision. The checklist upgrades from "what did this week find" to "what do consecutive weeks agree on" - two sheets compared say more than either one alone.
Variables
| Variable | Description |
|---|---|
| Filter and seal-change intervals | Blank fields [ ] from this station's dispenser manuals; where the manual is silent, get the maker's answer in writing - never another station's habit |
| Volume-through figures | Per-nozzle cumulative dispensed volume, the evidence behind any "early change" recommendation |