N NoBullshit.wiki 中文

Dental clinic nurse - implant surgery day assist-and-circulate checklist - ordered by time (night-before review, before opening, circulating during, after closing), never by importance; patient identity and surgical site confirmed twice before draping; implant and graft lot numbers logged on the spot as the patient-site-lot triad; small instruments counted twice, before and after; every drug and threshold number left blank to follow the surgeon's orders and product labeling

Works with:Claude / GPT-4 classCategories:Dental ClinicLevel:Intermediate Updated

You are a nursing-support consultant for implant surgery days at
a dental clinic. Draft an "Implant Surgery Day Assist & Circulate
Checklist" for the assisting nurse to execute on surgery days.
One page, printed, posted on the surgical room wall or inside
the cart lid.

Ordering rule: items run in time order - "night-before review -
before opening - circulating during - after closing" - not in
importance order. Surgery-day errors are nearly all sequencing
errors: the site discrepancy surfaces after draping, the implant
lot never gets logged until after closing. Get the order right
and these errors have no place to occur.

Items (three columns each: what to do / pass standard / what to
do on the spot when it fails):

I. Night-before review (once the surgery schedule is fixed)
1. Surgery order carries five elements: patient ID / surgical
   site (tooth) / procedure / surgeon / planned implant
   specification. Anything missing - contact the scheduler
   tonight, do not carry it to morning.
2. Implants and graft material stocked: specification matches
   the order, within expiry, lot label intact and legible.
   Spec mismatch - swap tonight; expired stock does not enter
   the surgical room, period.
3. Surgical pack sterilization indicators: cycle traceable,
   indicator color-change passed. Anything off - re-sterilize
   or swap the pack tonight.
4. Surgical guide / casts and imaging on hand (per whether this
   case uses them).

II. Before opening (all done before the patient enters)
5. Room surfaces and equipment wiped and disinfected; suction
   lines running freely.
6. Instrument table zoned: soiled and clean zones physically
   separated; small instruments (drills and burs) arranged
   countably, starting count recorded.
7. Drug check: anesthetics plus emergency-cart drugs and items
   present and in date. The emergency-cart check is logged -
   no check, no opening.
8. Patient identity and site confirmed twice: name + surgical
   site, agreeing across the order, the imaging, and the
   consent form. This happens BEFORE draping. Any disagreement
   - stop and call the surgeon.
9. Allergies and systemic status asked one last time (blood
   pressure, diabetes, current medication, possible pregnancy).
   If asked, it must land in the chart - asked-but-unrecorded
   equals not asked.

III. Circulating during
10. Suction and isolation continuously effective; when the
    surgeon pauses, proactively re-scan the instrument table.
11. Before opening any implant or graft container: the
    circulating nurse reads the lot number aloud, a second
    person (surgeon or second staff) verifies, THEN it opens.
    The lot is logged on the spot as the triad - patient /
    site / lot - in the surgical nursing record, with the
    label or barcode affixed to the chart in the same step.
12. Everything handed over mid-surgery (irrigation and the
    like) is named aloud as it passes; empties stay in the
    room, pooled in one place.
13. Mid-surgery new requests (extra instrument, extra
    material): repeat the request aloud, confirm, act, then
    add one line to the record.

IV. After closing (begins before the patient leaves)
14. Second count of small instruments: against the opening
    count. Short - search the whole field; if not found, the
    room is not cleaned down and it escalates.
15. Implant logging closed out: triad complete, label affixed.
    Anything missing - complete it same day, marked as a late
    entry.
16. Instrument collection per the reprocessing flow; never
    pooled with general-chair instruments.
17. Sharps and clinical waste disposed; terminal room clean.
18. Post-op instructions sheet and the follow-up appointment
    slip handed to the escort or the front desk with a
    signature - handover is not complete until signed.

Constraints (on you):
- No antibiotics, analgesics, mouthrinse, or any other
  medication advice anywhere in the checklist - that is the
  surgeon's call; the checklist only verifies presence
- No blood-pressure, blood-glucose, or any other threshold
  numbers - our policy and the surgeon's orders decide
- Every pass standard is an observable action or state;
  "properly" and "correctly" are banned words
- Cap at 18 items; if it won't fit one page, cut items - never
  shrink the font

Why it is written this way

Implant day is the assisting nurse's most asymmetric day: perhaps a few dozen cases a year, each carrying error costs ordinary dentistry cannot approach. The checklist orders by time rather than importance because surgery-day errors are nearly all sequencing errors - an importance-ordered checklist makes "identity and site confirmation" look grand near the top, but the real gate is that it must occur before draping: discovering a site dispute after draping means either breaking the sterile field or continuing under doubt. Pinning each item to a moment in time beats adding exclamation marks to it.

Implant lot logging is built as an on-the-spot triad because a late entry is nearly as good as no entry in the implant setting: the patient and the site are what make this lot matter, and missing either breaks the trace. Reading the lot aloud with a second verifier before opening binds the irreversible act (opening) to the check - once opened, verification can only ever be memory. Affixing the label to the chart in the same step lets the nursing record and the chart testify to each other instead of telling two stories.

The two counts of small instruments (opening count, closing count) borrow an old operating-room rule because implant surgery shares the physics: many small drills, an obstructed field, and unacceptable consequences for a retained item. The checklist ends by making the handover of instruction sheets and appointment slips a signed act - the last link that drops on surgery days, when patient and family retain the least of what is said aloud. Paper leaves the building far more reliably than spoken advice.

Variables

Variable Notes
Cases per day With multiple surgeries in one day, run the checklist independently per case - the before-opening section never "inherits" the previous case's state; add one inter-case item for room wipe-down
Guide and casts Keep or drop item 4 per whether the case uses them; for digital guides, the check is guide ID against patient ID
Second person Lot verification needs a second person; in a single-assistant clinic the surgeon fills the role, and the checklist states the substitute wording "surgeon reads back aloud"
Nursing record medium The triad lands in the surgical nursing record or the dedicated implant log, whichever already exists here - do not start a parallel record

implant-surgerysurgical-assistingfour-handed