Mobile & digital repair technician - intake inspection must-record checklist - the moment a customer hands over a device, six records happen in order - four-side plus frame photos with the ticket number shot first, serial/model/color/variant entered, liquid-indicator state logged BEFORE opening, screen-lock and account-lock registered, fault reproduced on the spot (and if it won't reproduce, the words "customer-reported, not reproduced" are spoken aloud and recorded), and data keep-or-wipe signed - the work order cannot even be created until all six are done, killing the two unwinnable arguments: "the scratch was your shop" and "where are my photos"
You are a repair-process consultant
for mobile-and-digital retail. Build
a must-record checklist for "intake
inspection", used by bench technicians
at the counter the moment a customer
hands over a device. Target: six
records complete before the work
order exists; missing any one, the
order cannot be created.
Preamble (for the technician):
Intake records are not paperwork -
they are this device's birth
certificate for its entire stay. When
a dispute comes, memories are useless
on both sides; only this sheet works.
Skip the first minute of recording
and spend the last hundred minutes
arguing.
Six must-records (in intake order;
each states HOW to record):
Record 1 - appearance imagery
- How: one shot each of front, back,
both frame sides, plus a close-up
of any visible scratch or dent
- Iron rule: the FIRST photo is
always the ticket number (photograph
the handwritten slip header, or the
on-screen order number) - photos
and tickets stay cross-findable
forever; that one shot is the key
to every photo after it
- Blurry shots get a retake; originals
are never deleted
Record 2 - identity
- How: body serial (from Settings or
the dialer code), full model,
storage variant, color - each into
the work order
- The serial recorded is the one the
system reports; the etched back and
the box are secondary - trusting
the etch first is how relabeled
resealed units slip through
Record 3 - liquid-indicator state
- How: before opening, visually check
the visible spots (SIM tray, port
area) and log "no discoloration
seen" or what was seen; after
opening, add photos of the board
indicators to the ticket
- Note: this record's timestamp is
BEFORE disassembly - recorded after
opening, no one can say whether
discoloration predates the opening
Record 4 - passwords and locks
- How: the customer types the screen
lock into the ticket's password
field themselves; account-lock
state (signed out / still active)
recorded per unit
- Discipline: passwords live in the
password field only - never in
chats, never relayed verbally
Record 5 - fault reproduction
- How: reproduce the fault in front
of the customer; on success, log
the symptom and its conditions
("appears after ten minutes
charging")
- On failure: speak this sentence to
the customer verbatim and log it -
"I can't make the fault appear
right now, so I'm recording it as
'customer-reported, not
reproduced', and we'll focus the
repair there." Saying it aloud lets
the customer hear and accept it now,
pre-empting the later "you said
there was no fault" deadlock
Record 6 - data keep-or-wipe
- How: ask and log the customer's
exact words - "keep my data" or
"don't worry about it"; for keep,
state: "some repair paths wipe
data; we'll choose data-preserving
options first, but a hundred
percent is not guaranteed" - until
the customer acknowledges
- Customer signs the ticket's data
field or confirms electronically
Order-creation gate: six records
complete, then the work order may be
generated. Build the six as
checkboxes on the ticket - paper or
system - and let the flow refuse to
advance with any box unchecked.
Forbidden:
- A non-reproducing fault is never
logged as "fault exists" - log what
was seen and what was reported
- No intake photo is deleted, blurry
ones included (a blurry shot still
proves "we photographed it then")
- Appearance photos are never skipped
on machines that "look brand new" -
the most expensive disputes happen
on exactly those
- No verbal promises of "definitely
fixable" or "data one hundred
percent safe"
- The customer's password appears
nowhere except the password field
Output: one laminated bench card -
front, the six records (each with how
and iron rules); back, the creation
gate and forbidden items; plus field
design notes for the six checkboxes
on the work order.
Why it is written this way
"First photo is the ticket number" is the cheapest, highest-value design on the sheet. A bench photographs dozens of units a day; finding "that machine's scratch shot" later means remembering time order, and memory fails. Shooting the ticket number first gives every photo batch its own index - photos map to tickets, tickets map to units, always. One gesture turns "photo evidence" from a theory into something usable.
Record 3 pins its timestamp before disassembly to break an unanswerable loop: the unit comes open, the indicator shows discoloration, and the customer asks "did that happen while YOU had it open?" - with nothing recorded, no answer survives. The pre-opening visual note (even just "tray-area indicator clear") plus the post-opening photos lock the state change inside the disassembly window, and the responsibility boundary with it.
Record 5's "say it aloud" is the least technical and most effective action on the list. "Customer-reported, not reproduced" written silently on a slip can be denied later; spoken to the customer's face it gets heard and tacitly accepted on the spot - a vaccine against the after-the-fact "you said there was nothing wrong". Intermittent faults are the heavy disaster zone of repair disputes; this record exists for them.
Record 6 logs the customer's exact words and forbids summarizing them into "data confirmed", because "don't worry about it" and "must save it" are two entirely different repair constraints, and a summary erases the difference. And "not a hundred percent guaranteed" must be said at intake - it is the most honest risk disclosure in the repair trade: said now, a data wipe is a disclosed risk; unsaid, it is an incident.
Variables
| Variable | Description |
|---|---|
| Photo retention policy | Where intake photos live and for how long - the ticketing system's attachments are best; stores without one archive monthly to encrypted storage, retained at least through the store's own warranty-dispute window |
| Password-field design | The concrete form of the ticket password field - a peel-off strip on paper slips, or a permissioned field in a system; visible at pickup verification, invisible everywhere else |
| Data-confirmation method | The form of record 6's confirmation - paper signature, SMS link, or in-app checkbox; electronic confirmations attach their confirmation record to the ticket |