Mobile & digital loss prevention - demo-unit open/close put-away and verification SOP - at close, collect live units slot by slot off the experience-bar map, reading each serial against the log as it goes into the cabinet, dummies placed back on the bar; at open, bring units out slot by slot, re-verify serials, check no new screen lock, reset tethers; dual signature on the put-away sheet, cameras live before starting, and a hard time limit - preventing the most expensive mismatch of all, "a live unit went out in the morning, a dummy came back at night"
You are a loss-prevention process
consultant for mobile-and-digital
retail. Turn "demo-unit put-away at
open and close" into an archivable
SOP for loss-prevention staff and the
shift crew.
Premises (the whole SOP stands on
these three):
- Demo units are sellable live stock;
put-away runs on asset-handover
standards, not on "tidying the
counter"
- The entire process must sit inside
effective camera coverage - no
cameras, no put-away; fix the
cameras first
- Each put-away completes within
[N minutes]; overrunning is itself
a reportable event (the usual
reason a put-away stretches is
"waiting on a serial to match",
and the longer the wait, the less
traceable the mismatch)
Close - collect (five steps, order
fixed):
1. Take the sheet: pull today's
put-away log; confirm last open's
placement record is complete (if
the last record is incomplete, the
cabinet stays shut - investigate
the last session first)
2. Collect slot by slot: starting at
slot 1 on the experience-bar map,
collect each unit and read the
last six digits of its body serial
aloud against the registered
serial for that slot - check as
you collect; "collect everything,
then check" is forbidden
3. Cabinet: verified units go to
their cabinet slots; a second
person confirms the cabinet locked
4. Refill: emptied bar slots get a
dummy or a "back shortly" card -
an empty slot at tomorrow's open
announces "the units here are not
watched"
5. Sign: dual signature (doer,
checker) on the log: date / time
/ expected count / actual count /
per-slot serial check result /
exception column
Open - place (five steps, mirror of
close):
1. Take the sheet: last night's
close record complete, cabinet
locks undisturbed (tampered lock
= do not open; report to the
manager first)
2. Out slot by slot: bring each unit
out and re-verify the serial (last
six digits) before it leaves the
cabinet area
3. Bench check: before each unit
goes on the bar, power it on -
system reachable, no new screen
lock, demo mode active; failures
do not go on the bar - route to
today's repair and inspection
flow
4. Tether reset: attach the security
tether and trigger-test [M] units
per day, rotating until every slot
is covered
5. Dual sign: date / time / expected
/ placed / bench-check result /
exception column
Exception handling (any step where a
serial fails to match):
- Stop at that slot; touch nothing;
do not refill ahead
- Report to the manager; pull camera
footage for that window
- Record verbatim in the exception
column: which slot, what was seen
(a dummy, an empty slot, or a
serial that doesn't match)
- Close it that night or open a case;
no unresolved doubts overnight
Forbidden (write into the SOP annex):
- Never "collect first, check after"
- the collecting IS the checking;
check after, and no one will ever
know at which step a mismatch was
born
- Never single-person cabinet access
- dual-person is not distrust; it
is your testimony when something
goes wrong
- Never skip the dummy refill
- Never handle a slot mismatch with
"close enough" or "check it
tomorrow"
- Put-away logs are bound and
archived monthly, kept [K months]
for review
Output: a printable SOP - two pages
of procedure (close five steps, open
five steps, exception handling), a
put-away log template (per-slot
serial check table mapped to the bar
layout), and a one-page staff quick-
reference card.
Why it is written this way
"Check as you collect, never after" is the SOP's soul clause. Check after, and a discovered mismatch tells you only "the count is off by one" - not whether the swap happened on the bar, in the handover, or into the cabinet slot, three possibilities pointing at three completely different responses. Embedding the check inside the action exposes the mismatch at the slot where it happened, handing the camera review a precise window. The clause costs a few extra minutes per close and buys the difference between "unexplainable" and "exactly here".
The dummy refill is a mandatory step because an empty bar slot is information leakage: at tomorrow's open, anyone familiar with the store sees "that position is missing a unit" - an announcement of where the defense is thin. A card works as well and cheaper; either one must go in. The bare empty slot is the worst choice available.
"No new screen lock" is listed separately in the open flow because it is the check most often skipped: fine at close, locked at open - someone touched that unit after closing, which makes it a loss-prevention lead, not a function fault. Placing it in the open flow rather than the patrol flow keeps that lead fresh when it is recorded.
The annex sentence for the dual-person rule - "not distrust; your testimony" - is not sentiment, it is what gives the SOP its lifespan: a document staff read as "guards against me" turns into signature theater within two weeks; one read as "protects me" keeps getting actually executed. The time limit works the same way - the most common stretched put-away is "stuck at a slot that won't match", and the limit promotes it from silently burning time to a reportable event.
Variables
| Variable | Description |
|---|---|
| Put-away time limit N minutes | Per-session completion limit - size to slot count (rough rule: a minute per unit plus cabinet time); too loose destroys the "overrun equals anomaly" signal, too tight pushes people to skip checks |
| Daily tether test count M | How many units get the alarm trigger test daily - testing everything is safest but slow; rotating spot-tests balance it, provided the rotation sheet is kept so the same units aren't always the tested ones |
| Log retention K months | How long put-away sheets are archived - per internal control and local record-keeping requirements; the archive exists for post-mismatch tracing, so retention should at least cover one full inventory-count cycle |